Ideal Logic and Logic+ fault codes
A code-by-code guide to what's gone wrong on an Ideal Logic or Logic+ boiler, the part it points to, and whether the fix needs a Gas Safe registered engineer.
Browse fault code guides for other boiler brandsReading the fault code on your Ideal Logic display
An Ideal Logic or Logic+ boiler shows a fault as a short code on the front display, usually a letter followed by a number, sometimes with a lock symbol if the boiler has gone into lockout. The code itself is only half the story. The same letter and number can point to a different part depending on which Logic variant you have and when it was built, so the first job is working out exactly what boiler is in front of you before you order anything.
Finding the model range
The model name is printed on the boiler's data badge, usually inside the front casing or on a label near the bottom edge. Ideal's Logic range covers several families, including Logic, Logic+ and Logic Max, each sold as a combi, system or heat-only variant. These are not interchangeable for parts purposes. A Logic+ combi and a Logic Max combi can display the same fault code for entirely different reasons, because the boards, sensors and control logic changed between ranges.
Finding the serial number
The serial number sits on the same data badge as the model name, typically as a long numeric string. It matters here because Ideal revised components and wiring within a single model range over its production life, and a part number correct for an early Logic+ can be wrong for a later one. Where a fault code page or parts listing asks for a serial range, checking the badge against it before ordering saves a return.
Finding the firmware version
Some Logic and Logic+ boards display a firmware or software version briefly on power-up, or through a service menu accessed via the front controls. Not every fault code behaves identically across firmware revisions, particularly where Ideal updated the control logic to change how a sensor fault is reported. If a code doesn't match the description given for your model, an older or newer firmware version is worth checking before assuming the code has been misread.
Before you go further
- Note the exact code shown, including any letter suffix
- Record the model name from the data badge
- Record the serial number from the data badge
- Check for a firmware version on power-up or in the service menu, if your model shows one
With those four details to hand, a fault code can be matched to the right component and the right part number. Some replacements are straightforward for a competent homeowner; others involve gas-carrying components and must be carried out by a Gas Safe registered engineer. For the rules on which is which, see the Gas Safe rules for boiler repairs guide. If your boiler is a different make, the fault code tables and part numbers won't apply, so check the guide for your specific brand on the boiler brands page instead.
Comparing common Ideal Logic fault codes
Ideal Logic and Logic+ boilers use the same letter-number codes across several model years, but what a code points to can shift between variants and firmware versions. Use this as a starting grouping, then check the specific code on your own display against its own entry.
| Fault code | What it usually means | Likely component | Gas Safe requirement |
|---|---|---|---|
| F1 | Ignition lockout: the burner did not light within the number of attempts the control board allows | Ignition electrode, gas valve, or the PCB itself, depending on what else is checked | Gas Safe registered engineer required |
| F2 | Flame loss: a flame was detected at start-up but then lost during operation | Flame sensor (rectification electrode) or the PCB reading it | Gas Safe registered engineer required |
| Other ignition or flame lockouts | Related lockout codes shown on some Logic and Logic+ variants for similar ignition or flame problems | Depends on the model and firmware version, so check the code against your own display | Gas Safe registered engineer required, since these all involve the gas train |
| Non-gas fault codes | Codes pointing to pressure, sensor, or pump problems | Pressure sensor, expansion vessel, pump, or PCB, depending on the exact code | Some are DIY-permissible, but confirm this against the specific fault code before starting |
This groups fault codes by type rather than listing every variant, and it does not replace checking the exact code, model, and firmware shown on your boiler's display.
Fault code F1 (ignition lockout)
F1 is the ignition lockout code on an Ideal Logic boiler, and it's usually the first fault code an owner ever sees. It means the boiler tried to light the burner, did not detect a flame within the time it allows, and shut itself down.
What's actually going wrong
A lockout on ignition can come from several places along the same chain: gas reaching the burner, a spark forming to light it, and the flame being sensed once it's lit. If any one of those steps fails, the boiler reads it as a failed ignition attempt and locks out after the permitted number of tries.
Components worth checking
- Gas supply - a closed valve elsewhere in the house, or a meter that's tripped, will produce the same code as a faulty part inside the boiler.
- Ignition electrode - the spark gap can close up or carbon over with age, weakening the spark that lights the gas.
- Flame sensor (NTC sensor) - if the boiler can't confirm the flame is burning once lit, it treats the attempt as failed even when ignition actually occurred.
- Gas valve - a valve that isn't opening fully will starve the burner of gas at the moment of ignition.
- Printed circuit board (PCB) - less common, but a fault here can misread a healthy flame signal as absent.
The most common cause on an Ideal Logic is a worn or misaligned ignition electrode, but that's a statement about frequency, not a diagnosis for any one boiler.
Why the part number depends on the model
The Logic and Logic+ ranges have gone through several revisions, and the electrode, flame sensor and PCB fitted to an early Logic combi are not always interchangeable with a later Logic+ model. Checking the model range and serial number against the fault code reference table elsewhere in this guide, and against the label on the part itself, is the way to confirm which part number applies before ordering anything.
What you can do yourself
Checking that the gas supply is on, the boiler has power, and nothing else in the house has tripped is fine for anyone to do. Opening the casing to inspect or replace the ignition electrode, gas valve or flame sensor is not. This work must be carried out by a Gas Safe registered engineer. The Gas Safe rules for boiler repairs guide sets out where that line sits in more detail, and if the PCB turns out to be the fault, the PCB replacement guide covers identifying and sourcing the right board.
Fault code F2: flame loss and the flame sensor
Fault code F2 means the boiler tried to light and either failed to detect a flame or lost the flame signal after ignition. That is a different failure point to F1, which is a straightforward ignition lockout where the burner never lit at all. F2 usually means the burner did light, at least briefly, but the boiler could not confirm it was still burning and shut down as a safety response.
How the flame sensor fits in
The flame sensor (sometimes called the flame rectification probe) sits in the combustion chamber next to the burner. Once the boiler ignites, it uses this probe to check for a genuine flame signal, and it keeps checking for as long as the burner is firing. If the signal drops out, weakens, or was never clean to begin with, the printed circuit board (PCB) reads that as flame loss and stops the boiler.
A weak or dirty flame sensor is the most common reason for F2. Carbon deposits on the probe tip, poor earthing, or a probe positioned slightly out of the flame can all produce a signal too weak for the PCB to trust, even though the burner is actually alight.
What else can trigger F2
- A flame sensor that is fouled, corroded, or has drifted out of position
- Poor gas pressure or an unstable flame at the burner, which gives the sensor nothing reliable to read
- A faulty gas valve that is not delivering a consistent flame
- Wiring or an earthing fault between the sensor and the PCB
- A PCB that is misreading a perfectly good flame signal
That last point is the one worth taking seriously before reaching for a new circuit board. A PCB fault is the least common cause of F2, and it should be considered only once the flame sensor, its wiring, and the gas supply to the burner have been checked and ruled out.
When a PCB replacement is indicated
Replacing the PCB is indicated when a known-good flame sensor still produces an unstable or absent signal at the board, or when the board fails to respond correctly to a signal that testing confirms is present and clean. Combustion and gas valve components sit behind this fault, so diagnosing it properly means working on gas-carrying parts. This work must be carried out by a Gas Safe registered engineer.
For the part numbers behind F2 and the model ranges they apply to, see the fault code reference table on this page. If you are unsure whether the work in front of you falls inside or outside DIY territory, the rules are set out in full in our Gas Safe rules for boiler repairs guide.
Common questions
Does an Ideal Logic fault code always mean the same part has failed?
No. The same code can point to different components depending on the model range, the firmware version and how long the fault has been present. Two boilers showing F1 can need different parts, so the model and serial details on the rating plate matter before you order anything.
Can I reset the boiler myself when a fault code appears?
Pressing the reset button is usually fine and does no harm. If the fault clears and stays clear, that's often enough. If the code returns within a day or two, resetting again just delays finding the actual cause, and a component has likely failed.
Will a compatible part work as well as the original Ideal part?
A compatible part built to the same specification will normally do the job the OEM part does. The connector type, mounting and sensor rating still need to match your specific model, which is why checking the physical part against your boiler's label matters more than the brand printed on the box.
How much does it cost to fix a fault code repair?
It depends on which component has failed and whether the job is DIY-permissible or needs a Gas Safe registered engineer. A thermistor or a sensor is a different job to a PCB or a heat exchanger, both in parts and in labour, so there's no single figure that covers every fault code.
Do I need a Gas Safe registered engineer for every Ideal Logic repair?
Not every repair, but any work on a gas-carrying component does. This includes the gas valve and anything connected to it, and it must be carried out by a Gas Safe registered engineer. Work on electrical components away from the gas side, such as some pumps or sensors, can fall outside that restriction, but it's worth confirming before you start.
What if my fault code isn't listed anywhere?
Some intermittent faults display briefly and clear before you can note the full code, or the boiler is an older variant with its own code set. Where that happens, the serial number and model plate are the starting point for narrowing down what the display was actually telling you.
Know the part, then check what fitting it involves.